BURY CABLE supplies this medium voltage XLPE cable for fixed power distribution in substations, industrial plants and utility networks. Its overall screened, unarmoured construction suits ducts, trays and protected trenches where the route provides the required mechanical protection.
IEC 60228
IEC 60502-2
Conductor : Stranded bare copper (class 2)
Conductor screen : This will be an extruded layer of semi-conducting crosslinkable compound applied under simultaneous triple extrusion process over the conductor along with the insulation and the insulation screen.
Insulation : XLPE
Insulation screen : This will be a layer of semi-conducting crosslinkable compound which will be applied by triple extrusion process over the insulation.
Core identification
1 Core : Natural
3 Cores : Black, Green, Brown
Inner sheath : PVC Color black
Overall screen : Aluminum/polyethylene tape
Sheath : HDPE; Color : black
Special sheath (intermediate sheath) : Polyamide
Outer sheath : Special PVC. Color : red. U.V resistance can be offered upon request.
Fire retardance : IEC 60332-3-22
Operating temperature : -20~60°C
Max. conductor operating temperature : 90°C
Chemical resistance : Aliphatic and aromatic hydrocarbon resistance
Class 2 stranded copper with XLPE insulation and triple-extruded semiconducting conductor and insulation screens.
Overall aluminium/polyethylene tape screen with PVC inner sheath, HDPE and polyamide layers.
Red special PVC outer sheath, with UV resistance available as an option.
Specify system voltage U0/U(Um), core count, conductor size, circuit length, load and installation conditions. Coordinate screen bonding, fault duty and terminations with the network design.
Select mechanical protection for the route and match accessories to the agreed cable dimensions. Include any UV and chemical-exposure requirements in the order.
Use the stated -20 to 60°C operating range and 90°C maximum conductor temperature as separate selection limits.
Aluminium/polyethylene tape surrounds the cable assembly, alongside the separately described semiconducting conductor and insulation screens.
The construction includes PVC, HDPE and polyamide layers, finished with a red special PVC outer sheath.
Protected fixed routes in industrial and utility networks, including ducts, trays and trenches with suitable mechanical protection.
Class 2 stranded bare copper with XLPE insulation.
Provide the system voltage, core count, conductor size, route, load, screen bonding arrangement and required lengths to BURY CABLE.