BURY CABLE supplies this 600/1000V copper XLPE insulated cable for fixed low voltage power distribution in buildings, industrial plants and infrastructure. The unarmoured PVC-sheathed construction is intended for routes with suitable external mechanical protection, such as ducts, trays or protected trenches.
Conductor : Solid or stranded copper
Insulation : XLPE
1 Core : Red or Black
2 Cores : Red, Black
3 Cores : Red, Yellow, Blue
4 Cores : Red, Yellow, Blue, Black
5 Cores : Red, Yellow, Blue, Black, Green
Above 5 cores : Black core printed with white numbers
Sheath : Special PVC. Color : black
Rated voltage : 600V/1000V
Fire retardance : IEC 60332-3-22
Operating temperature : -20~60°C
Max. conductor operating temperature : 90°C
Chemical resistance : Aliphatic and aromatic hydrocarbon resistance
| No. of Cores | Conductor Corss-section | Conductor Type | Diameter over Insulation | Min. O.D. | Max. O.D. | Approx. Weight |
|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | kg/km | ||
| 1 | 25 | Stranded, Class 2 | 7.9 | 10.6 | 11.9 | 325 |
| 1 | 35 | Stranded, Class 2 | 8.9 | 11.6 | 13.0 | 422 |
| 1 | 50 | Stranded, Class 2 | 10.2 | 13.3 | 14.8 | 562 |
| 1 | 70 | Stranded, Class 2 | 12.0 | 16.1 | 17.8 | 807 |
| 1 | 95 | Stranded, Class 2 | 13.55 | 17.61 | 19.4 | 1057 |
| 1 | 120 | Stranded, Class 2 | 15.26 | 19.26 | 21.2 | 1296 |
| 1 | 150 | Stranded, Class 2 | 16.97 | 21.12 | 23.3 | 1585 |
| 1 | 185 | Stranded, Class 2 | 19.05 | 23.13 | 25.5 | 1962 |
| 1 | 240 | Stranded, Class 2 | 21.6 | 26.0 | 28.7 | 2547 |
| 1 | 300 | Stranded, Class 2 | 24.2 | 28.71 | 31.7 | 3162 |
| 1 | 400 | Stranded, Class 2 | 27.7 | 32.3 | 35.6 | 4010 |
| 1 | 500 | Stranded, Class 2 | 31.4 | 36.28 | 40.0 | 5111 |
| 1 | 630 | Stranded, Class 2 | 36.2 | 41.32 | 45.6 | 6560 |
| 2 | 1.5 | Solid, Class 1 | 2.79 | 9.38 | 10.6 | 143 |
| 2 | 1.5 | Stranded, Class 2 | 2.9 | 9.7 | 10.9 | 152 |
| 2 | 2.5 | Solid, Class 1 | 3.15 | 10.1 | 11.3 | 176 |
| 2 | 2.5 | Stranded, Class 2 | 3.31 | 10.6 | 11.9 | 189 |
| 2 | 4 | Solid, Class 1 | 3.61 | 11.02 | 12.3 | 224 |
| 2 | 4 | Stranded, Class 2 | 3.83 | 11.7 | 13.0 | 244 |
| 2 | 6 | Stranded, Class 2 | 4.35 | 12.5 | 13.9 | 297 |
| 2 | 10 | Stranded, Class 2 | 5.25 | 14.3 | 15.8 | 419 |
| 2 | 16 | Stranded, Class 2 | 6.25 | 16.3 | 18.0 | 586 |
| 2 | 25 | Stranded, Class 2 | 7.9 | 19.5 | 21.5 | 873 |
| 2 | 35 | Stranded, Class 2 | 8.9 | 21.44 | 23.6 | 1126 |
| 2 | 50 | Stranded, Class 2 | 10.2 | 24.06 | 26.5 | 1469 |
| 2 | 70 | Stranded, Class 2 | 12.0 | 27.55 | 30.4 | 2010 |
| 2 | 95 | Stranded, Class 2 | 13.55 | 30.55 | 33.7 | 2632 |
| 2 | 120 | Stranded, Class 2 | 15.26 | 33.87 | 37.4 | 3270 |
| 2 | 150 | Stranded, Class 2 | 16.97 | 37.77 | 41.7 | 4046 |
| 2 | 185 | Stranded, Class 2 | 19.05 | 42.0 | 46.3 | 5051 |
| 2 | 240 | Stranded, Class 2 | 21.6 | 47.34 | 52.2 | 6543 |
| 2 | 300 | Stranded, Class 2 | 24.2 | 52.77 | 58.2 | 8175 |
| 3 | 1.5 | Solid, Class 1 | 2.79 | 9.83 | 11.0 | 161 |
| 3 | 1.5 | Stranded, Class 2 | 2.9 | 10.17 | 11.4 | 170 |
| 3 | 2.5 | Solid, Class 1 | 3.15 | 10.6 | 11.9 | 202 |
| 3 | 2.5 | Stranded, Class 2 | 3.31 | 11.14 | 12.4 | 215 |
| 3 | 4 | Solid, Class 1 | 3.61 | 11.6 | 13.0 | 263 |
| 3 | 4 | Stranded, Class 2 | 3.83 | 12.33 | 13.7 | 284 |
| 3 | 6 | Stranded, Class 2 | 4.35 | 13.2 | 14.7 | 353 |
| 3 | 10 | Stranded, Class 2 | 5.25 | 15.14 | 16.7 | 508 |
| 3 | 16 | Stranded, Class 2 | 6.25 | 17.27 | 19.0 | 724 |
| 3 | 25 | Stranded, Class 2 | 7.9 | 20.72 | 22.9 | 1088 |
| 3 | 35 | Stranded, Class 2 | 8.9 | 22.81 | 25.2 | 1420 |
| 3 | 50 | Stranded, Class 2 | 10.2 | 25.64 | 28.3 | 1864 |
| 3 | 70 | Stranded, Class 2 | 12.0 | 29.41 | 32.4 | 2568 |
| 3 | 95 | Stranded, Class 2 | 13.55 | 32.66 | 36.0 | 3400 |
| 3 | 120 | Stranded, Class 2 | 15.26 | 36.43 | 40.2 | 4247 |
| 3 | 150 | Stranded, Class 2 | 16.97 | 40.41 | 44.6 | 5231 |
| 3 | 185 | Stranded, Class 2 | 19.05 | 45.15 | 49.8 | 6561 |
| 3 | 240 | Stranded, Class 2 | 21.6 | 50.69 | 55.9 | 8496 |
| 3 | 300 | Stranded, Class 2 | 24.2 | 56.91 | 62.8 | 10681 |
| 4 | 1.5 | Solid, Class 1 | 2.79 | 10.55 | 11.8 | 187 |
| 4 | 1.5 | Stranded, Class 2 | 2.9 | 10.94 | 12.2 | 197 |
| 4 | 2.5 | Solid, Class 1 | 3.15 | 11.42 | 12.8 | 238 |
| 4 | 2.5 | Stranded, Class 2 | 3.31 | 12.03 | 13.4 | 252 |
| 4 | 4 | Solid, Class 1 | 3.61 | 12.5 | 14.0 | 314 |
| 4 | 4 | Stranded, Class 2 | 3.83 | 13.36 | 14.8 | 337.2 |
| 4 | 6 | Stranded, Class 2 | 4.35 | 14.33 | 15.9 | 424 |
| 4 | 10 | Stranded, Class 2 | 5.25 | 16.5 | 18.2 | 625 |
| 4 | 16 | Stranded, Class 2 | 6.25 | 18.85 | 20.8 | 901 |
| 4 | 25 | Stranded, Class 2 | 7.9 | 22.72 | 25.1 | 1359 |
| 4 | 35 | Stranded, Class 2 | 8.9 | 25.16 | 27.8 | 1791 |
| 4 | 50 | Stranded, Class 2 | 10.2 | 28.21 | 31.1 | 2348 |
| 4 | 70 | Stranded, Class 2 | 12.0 | 32.44 | 35.8 | 3250 |
| 4 | 95 | Stranded, Class 2 | 13.55 | 36.27 | 40.0 | 4334 |
| 4 | 120 | Stranded, Class 2 | 15.26 | 40.67 | 44.9 | 5447 |
| 4 | 150 | Stranded, Class 2 | 16.97 | 44.88 | 49.5 | 6688 |
| 4 | 185 | Stranded, Class 2 | 19.05 | 50.34 | 55.5 | 8400 |
| 4 | 240 | Stranded, Class 2 | 21.6 | 56.72 | 62.6 | 10917 |
| 4 | 300 | Stranded, Class 2 | 24.2 | 63.4 | 69.9 | 13658 |
| 5 | 1.5 | Solid, Class 1 | 2.79 | 11.3 | 12.7 | 220 |
| 5 | 1.5 | Stranded, Class 2 | 2.9 | 11.77 | 13.1 | 232 |
| 5 | 2.5 | Solid, Class 1 | 3.15 | 12.3 | 13.7 | 281 |
| 5 | 2.5 | Stranded, Class 2 | 3.31 | 12.98 | 14.4 | 297 |
| 5 | 4 | Solid, Class 1 | 3.61 | 13.6 | 15.0 | 377 |
| 5 | 4 | Stranded, Class 2 | 3.83 | 14.47 | 16.0 | 403 |
| 5 | 6 | Stranded, Class 2 | 4.35 | 15.55 | 17.2 | 511 |
| 5 | 10 | Stranded, Class 2 | 5.25 | 17.93 | 19.8 | 747 |
| 5 | 16 | Stranded, Class 2 | 6.25 | 20.54 | 22.7 | 1082 |
| 5 | 25 | Stranded, Class 2 | 7.9 | 24.96 | 27.5 | 1650 |
| 5 | 35 | Stranded, Class 2 | 8.9 | 27.58 | 30.4 | 2185 |
| 5 | 50 | Stranded, Class 2 | 10.2 | 30.98 | 34.2 | 2873 |
| 5 | 70 | Stranded, Class 2 | 12.0 | 36.08 | 39.8 | 4017 |
| 5 | 95 | Stranded, Class 2 | 13.55 | 40.54 | 44.7 | 5364 |
| 5 | 120 | Stranded, Class 2 | 15.26 | 45.2 | 49.9 | 6678 |
| 5 | 150 | Stranded, Class 2 | 16.97 | 50.07 | 55.2 | 8197 |
| 5 | 185 | Stranded, Class 2 | 19.05 | 55.91 | 61.7 | 10257 |
| 5 | 240 | Stranded, Class 2 | 21.6 | 62.97 | 69.5 | 13310 |
| 5 | 300 | Stranded, Class 2 | 24.2 | 70.36 | 77.6 | 16650 |
| 7 | 1.5 | Stranded, Class 2 | 2.9 | 12.35 | 13.8 | 258 |
| 7 | 2.5 | Stranded, Class 2 | 3.31 | 13.7 | 15.2 | 341 |
| 10 | 1.5 | Stranded, Class 2 | 2.9 | 15.4 | 17.0 | 360 |
| 10 | 2.5 | Stranded, Class 2 | 3.31 | 17.17 | 18.9 | 479 |
| 12 | 1.5 | Stranded, Class 2 | 2.9 | 15.9 | 17.6 | 431 |
| 12 | 2.5 | Stranded, Class 2 | 3.31 | 17.65 | 19.5 | 581 |
| 14 | 1.5 | Stranded, Class 2 | 2.9 | 17.17 | 18.9 | 507 |
| 14 | 2.5 | Stranded, Class 2 | 3.31 | 19.11 | 21.1 | 683 |
| 19 | 1.5 | Stranded, Class 2 | 2.9 | 18.82 | 20.8 | 633 |
| 19 | 2.5 | Stranded, Class 2 | 3.31 | 21.05 | 23.2 | 863 |
| 24 | 1.5 | Stranded, Class 2 | 2.9 | 21.73 | 24.0 | 815 |
| 24 | 2.5 | Stranded, Class 2 | 3.31 | 24.35 | 26.9 | 1115 |
| 27 | 1.5 | Stranded, Class 2 | 2.9 | 22.12 | 24.4 | 872 |
| 27 | 2.5 | Stranded, Class 2 | 3.31 | 24.83 | 27.4 | 1201 |
| 30 | 1.5 | Stranded, Class 2 | 2.9 | 22.89 | 25.2 | 946 |
| 30 | 2.5 | Stranded, Class 2 | 3.31 | 25.7 | 28.4 | 1306 |
| 37 | 1.5 | Stranded, Class 2 | 2.9 | 24.64 | 27.2 | 1118 |
| 37 | 2.5 | Stranded, Class 2 | 3.31 | 27.64 | 30.5 | 1550 |
Solid or stranded copper conductors with XLPE insulation and black special PVC sheath.
Construction table identifies the conductor class, core count, insulation diameter, overall diameter range and approximate weight for each entry.
Maximum conductor operating temperature 90°C; the separately stated operating temperature range is -20 to 60°C.
Select the exact core count, conductor size and conductor class from the schedule. Specify load, circuit length, route, grouping, ambient conditions and allowable voltage drop for rating calculations.
Confirm core colours and protective conductor identification against the project rules. The stated operating temperature range and maximum conductor temperature are different limits.
Agree hydrocarbon exposure, flame-test requirements and sheath suitability with BURY CABLE. The IEC 60332-3-22 reference does not establish circuit integrity or a halogen-free construction.
No. Choose an armoured construction if required, or provide suitable mechanical protection along the route.
No. The schedule includes Class 1 solid and Class 2 stranded entries; select the required row.
No. It is the maximum conductor operating temperature. The listed operating range is separately stated as -20 to 60°C.
The sheath is special PVC. A halogen-free requirement needs a separately agreed cable construction.
Send load, voltage, core arrangement, route length, installation method, grouping and ambient conditions to BURY CABLE.