BURY CABLE supplies this 600/1000V multicore PVC insulated, steel wire armoured cable for fixed industrial and commercial power distribution. The inner covering, galvanized steel wire armour and PVC sheath provide an armoured construction for routes selected to suit the project conditions.
Basic design adapted to IEC 60502-1
| Flame Retardance (Single Vertical Wire Test) | IEC 60332-1-2 |
600/1000V
| Conductor | Annealed copper wire, stranded according to IEC 60228 class 2. |
| Insulation | PVC/A according to IEC 60502-1. |
| Inner Covering | Extruded PVC or polymeric compound. |
| Armouring | Galvanized steel wire |
| Outer Sheath | Extruded PVC Type ST1/ST2 according to IEC 60502-1. |
| Outer Sheath Option | UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. |
| Insulation Colour | Two-core: Brown, blue Three-core: Brown, black, grey Four-core: Blue, brown, black, grey Five-core: Green-and-yellow, blue, brown, black, grey Other colours can be offered upon request. |
| Sheath Colour | Black, other colours can be offered upon request. |
| Maximum temperature range during operation (PVC) | 70°C |
| Maximum short circuit temperature (5 Seconds) | 160°C(≤300 mm²); 140°C(>300 mm²) |
| Minimum bending radius | |
| Circular copper conductors | 6 x Overall Diameter |
| Shaped copper conductors | 8 x Overall Diameter |
| Conductor | FLP600-VVMV-R | |||||||
|---|---|---|---|---|---|---|---|---|
| No. of Cores x Cross Section | Class of Conductor | Nominal Insulation Thickness | Nominal Inner Covering Thickness | Armour Wire Diameter | Nominal Sheath Thickness | Nominal Overall Diameter | Approx. Weight | |
| No.xmm2 | mm | mm | mm | mm | mm | kg/km | ||
| 2 Cores | ||||||||
| 2x2.5 | 2 | 0.8 | 1.0 | 0.8 | 1.8 | 14.0 | 380 | |
| 2x4.0 | 2 | 1.0 | 1.0 | 1.25 | 1.8 | 16.7 | 604 | |
| 2x6.0 | 2 | 1.0 | 1.0 | 1.25 | 1.8 | 17.7 | 689 | |
| 2x10 | 2 | 1.0 | 1.0 | 1.25 | 1.8 | 19.3 | 841 | |
| 2x16 | 2 | 1.0 | 1.0 | 1.25 | 1.8 | 21.1 | 1037 | |
| 2x25 | 2 | 1.2 | 1.0 | 1.6 | 1.8 | 24.8 | 1513 | |
| 2x35 | 2 | 1.2 | 1.0 | 1.6 | 1.8 | 27.0 | 1843 | |
| 2x50 | 2 | 1.4 | 1.0 | 1.6 | 1.9 | 30.7 | 2356 | |
| 2x70 | 2 | 1.4 | 1.0 | 2.0 | 2.1 | 34.5 | 3179 | |
| 2x95 | 2 | 1.6 | 1.2 | 2.0 | 2.2 | 39.2 | 4042 | |
| 2x120 | 2 | 1.6 | 1.2 | 2.0 | 2.3 | 42.2 | 4764 | |
| 2x150 | 2 | 1.8 | 1.2 | 2.5 | 2.5 | 47.2 | 6095 | |
| 2x185 | 2 | 2.0 | 1.4 | 2.5 | 2.6 | 51.6 | 7207 | |
| 2x240 | 2 | 2.2 | 1.4 | 2.5 | 2.8 | 57.2 | 8861 | |
| 2x300 | 2 | 2.4 | 1.6 | 2.5 | 3.0 | 62.8 | 10608 | |
| 2x400 | 2 | 2.6 | 1.6 | 2.5 | 3.2 | 70.3 | 13385 | |
| 3 Cores | ||||||||
| 3x2.5 | 2 | 0.8 | 1.0 | 0.8 | 1.8 | 14.5 | 432 | |
| 3x4.0 | 2 | 1.0 | 1.0 | 1.25 | 1.8 | 17.4 | 689 | |
| 3x6.0 | 2 | 1.0 | 1.0 | 1.25 | 1.8 | 18.4 | 800 | |
| 3x10 | 2 | 1.0 | 1.0 | 1.25 | 1.8 | 20.2 | 1001 | |
| 3x16 | 2 | 1.0 | 1.0 | 1.6 | 1.8 | 22.8 | 1405 | |
| 3x25 | 2 | 1.2 | 1.0 | 1.6 | 1.8 | 26.0 | 1860 | |
| 3x35 | 2 | 1.2 | 1.0 | 1.6 | 1.9 | 28.5 | 2325 | |
| 3x50 | 2 | 1.4 | 1.0 | 2.0 | 2.0 | 33.3 | 3266 | |
| 3x70 | 2 | 1.4 | 1.2 | 2.0 | 2.1 | 37.0 | 4108 | |
| 3x95 | 2 | 1.6 | 1.2 | 2.0 | 2.3 | 41.6 | 5245 | |
| 3x120 | 2 | 1.6 | 1.2 | 2.5 | 2.4 | 45.9 | 6677 | |
| 3x150 | 2 | 1.8 | 1.4 | 2.5 | 2.6 | 50.4 | 8016 | |
| 3x185 | 2 | 2.0 | 1.4 | 2.5 | 2.7 | 54.8 | 9466 | |
| 3x240 | 2 | 2.2 | 1.5 | 2.5 | 2.9 | 61.2 | 11805 | |
| 3x300 | 2 | 2.4 | 1.6 | 2.5 | 3.1 | 66.8 | 14181 | |
| 3x400 | 2 | 2.8 | 1.6 | 3.15 | 3.4 | 76.7 | 19235 | |
| 3x500 | 2 | 2.8 | 1.8 | 3.15 | 3.7 | 83.6 | 23011 | |
| 3 Cores+1 Earth Conductor | ||||||||
| 3x10/6 | 2 | 1.0 | 1.0 | 1.0 | 1.25 | 1.8 | 21.9 | 1140 |
| 3x16/10 | 2 | 1.0 | 1.0 | 1.0 | 1.6 | 1.8 | 24.2 | 1633 |
| 3x25/16 | 2 | 1.2 | 1.0 | 1.0 | 1.6 | 1.8 | 27.9 | 2145 |
| 3x35/16 | 2 | 1.2 | 1.0 | 1.0 | 1.6 | 1.9 | 30.8 | 2659 |
| 3x50/25 | 2 | 1.4 | 1.2 | 1.0 | 2.0 | 2.0 | 36.4 | 3739 |
| 3x70/35 | 2 | 1.4 | 1.2 | 1.2 | 2.0 | 2.1 | 40.1 | 4720 |
| 3x95/50 | 2 | 1.6 | 1.4 | 1.2 | 2.5 | 2.3 | 46.3 | 6398 |
| 3x120/70 | 2 | 1.6 | 1.4 | 1.4 | 2.5 | 2.4 | 50.3 | 7746 |
| 3x150/70 | 2 | 1.8 | 1.4 | 1.4 | 2.5 | 2.6 | 55.0 | 9128 |
| 3x185/95 | 2 | 2.0 | 1.6 | 1.4 | 2.5 | 2.7 | 60.3 | 10916 |
| 3x240/120 | 2 | 2.2 | 1.6 | 1.6 | 2.5 | 2.9 | 67.0 | 13713 |
| 3x300/150 | 2 | 2.4 | 1.8 | 1.6 | 3.15 | 3.1 | 74.6 | 17403 |
| 3x400/185 | 2 | 2.6 | 2.0 | 1.8 | 3.15 | 3.4 | 84.1 | 20704 |
| 3x500/240 | 2 | 2.8 | 2.2 | 2.0 | 3.15 | 3.7 | 91.8 | 25817 |
| 4 Cores | ||||||||
| 4x4.0 | 2 | 1.0 | 1.0 | 1.25 | 1.8 | 18.5 | 792 | |
| 4x6.0 | 2 | 1.0 | 1.0 | 1.25 | 1.8 | 19.7 | 931 | |
| 4x10 | 2 | 1.0 | 1.0 | 1.25 | 1.8 | 22.3 | 1185 | |
| 4x16 | 2 | 1.0 | 1.0 | 1.6 | 1.8 | 24.5 | 1672 | |
| 4x25 | 2 | 1.2 | 1.0 | 1.6 | 1.9 | 28.2 | 2260 | |
| 4x35 | 2 | 1.2 | 1.0 | 1.6 | 2.0 | 31.1 | 2854 | |
| 4x50 | 2 | 1.4 | 1.0 | 2.0 | 2.1 | 36.7 | 4013 | |
| 4x70 | 2 | 1.4 | 1.2 | 2.0 | 2.3 | 40.4 | 5104 | |
| 4x95 | 2 | 1.6 | 1.2 | 2.5 | 2.5 | 46.6 | 6996 | |
| 4x120 | 2 | 1.6 | 1.4 | 2.5 | 2.6 | 50.6 | 8400 | |
| 4x150 | 2 | 1.8 | 1.4 | 2.5 | 2.7 | 55.3 | 10008 | |
| 4x185 | 2 | 2.0 | 1.4 | 2.5 | 2.9 | 60.6 | 11906 | |
| 4x240 | 2 | 2.2 | 1.6 | 2.5 | 3.1 | 67.3 | 14963 | |
| 4x300 | 2 | 2.4 | 1.6 | 3.15 | 3.4 | 74.9 | 18944 | |
| 4x400 | 2 | 2.6 | 1.8 | 3.15 | 3.7 | 84.4 | 24304 | |
| 4x500 | 2 | 2.8 | 2.0 | 3.15 | 3.9 | 92.1 | 29351 | |
Note: Other conductor sizes & core confi gurations are available upon request.
| Conductor Operating Temperature | 70°C |
| Ambient Temperature | 30°C |
| Conductor crosssectional area | Reference Method C (clipped direct) | Reference Method E (in free air or on a perforated cable tray, horizontal or vertical) | Reference Method D (direct in in groud or in ducting in groud. in or around buildings) | |||
|---|---|---|---|---|---|---|
| 1 two-core cable, single-phase a.c. or d.c. | 1 three-or four core cable, three-phase a.c. | 1 two-core cable, singlephase a.c. or d.c. | 1 three-or four core cable, three-phase a.c. | 1 two-core cable, single-phase a.c. or d.c. | 1 three-or four core cable, threephase a.c. | |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
| mm2 | A | A | A | A | A | A |
| 1.5 | 21 | 18 | 22 | 19 | 22 | 18 |
| 2.5 | 28 | 25 | 31 | 26 | 29 | 24 |
| 4.0 | 38 | 33 | 41 | 35 | 37 | 30 |
| 6.0 | 49 | 42 | 53 | 45 | 46 | 38 |
| 10 | 67 | 58 | 72 | 62 | 60 | 50 |
| 16 | 89 | 77 | 97 | 83 | 78 | 64 |
| 25 | 118 | 102 | 128 | 110 | 99 | 82 |
| 35 | 145 | 125 | 157 | 135 | 119 | 98 |
| 50 | 175 | 151 | 190 | 163 | 140 | 116 |
| 70 | 222 | 192 | 241 | 207 | 173 | 143 |
| 95 | 269 | 231 | 291 | 251 | 204 | 169 |
| 120 | 310 | 267 | 336 | 290 | 231 | 192 |
| 150 | 356 | 306 | 386 | 332 | 261 | 217 |
| 185 | 405 | 348 | 439 | 378 | 292 | 243 |
| 240 | 476 | 409 | 516 | 445 | 336 | 280 |
| 300 | 547 | 469 | 592 | 510 | 379 | 316 |
| 400 | 621 | 540 | 683 | 590 | - | - |
| Nominal Cross Section Area | Two-core cables d.c. | Two-core cable, single-phase a.c. | Three- or four-core cable, three-phase a.c. | ||||
|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | ||||
| mm2 | mV/A/m | mV/A/m | mV/A/m | ||||
| 1.5 | 29 | 29 | 25 | ||||
| 2.5 | 18 | 18 | 15 | ||||
| 4.0 | 11 | 11 | 9.5 | ||||
| 6.0 | 7.3 | 7.3 | 6.4 | ||||
| 10 | 4.4 | 4.4 | 3.8 | ||||
| 16 | 2.8 | 2.8 | 2.4 | ||||
| r | x | z | r | x | z | ||
| 25 | 1.75 | 1.75 | 0.170 | 1.75 | 1.50 | 0.145 | 1.50 |
| 35 | 1.25 | 1.25 | 0.165 | 1.25 | 1.10 | 0.145 | 1.10 |
| 50 | 0.93 | 0.93 | 0.165 | 0.94 | 0.80 | 0.140 | 0.81 |
| 70 | 0.63 | 0.63 | 0.160 | 0.65 | 0.55 | 0.140 | 0.57 |
| 95 | 0.46 | 0.47 | 0.155 | 0.50 | 0.41 | 0.135 | 0.43 |
| 120 | 0.36 | 0.38 | 0.155 | 0.41 | 0.33 | 0.135 | 0.35 |
| 150 | 0.29 | 0.30 | 0.155 | 0.34 | 0.26 | 0.130 | 0.29 |
| 185 | 0.23 | 0.25 | 0.150 | 0.29 | 0.21 | 0.130 | 0.25 |
| 240 | 0.180 | 0.190 | 0.150 | 0.24 | 0.165 | 0.130 | 0.21 |
| 300 | 0.145 | 0.155 | 0.145 | 0.21 | 0.135 | 0.130 | 0.185 |
| 400 | 0.105 | 0.115 | 0.145 | 0.185 | 0.100 | 0.125 | 0.160 |
Note: *Spacings larger than one cable diameter will result in a large voltage drop.
r = conductor resistance at operating temperature
x = reactance
z = impedance
Class 2 annealed copper conductors, PVC/A insulation, inner covering, galvanized steel wire armour and PVC ST1/ST2 sheath.
Construction data for 2-, 3- and 4-core cables and 3 cores plus earth; conductor size ranges vary by configuration.
Maximum conductor operating temperature 70°C, with separate limits for bending and short circuit duty.
Confirm the exact core configuration, conductor sizes, earth conductor, route, load, length and installation environment. Use the matching construction row for gland and handling dimensions.
Select current rating and voltage drop data for the actual circuit and installation method, with ambient and grouping corrections. Confirm armour bonding and protective conductor requirements.
For buried or outdoor routes, agree soil, moisture, mechanical and UV conditions with BURY CABLE. Optional sheath performance and fire tests require an agreed specification.
Galvanized steel wire armour around the multicore assembly.
No. Use the separate single core AWA product when aluminium wire armour is required.
Yes. Their power and earth conductor sizes are shown separately in the construction table.
Use the stated limit for circular or shaped conductors and the actual overall diameter of the selected cable.
No. Confirm the armour bonding, protective conductor sizing, fault duty and termination arrangement for the installation.